The DTRO system can be operated in a flexible manner and can be selected as primary or secondary treatment according to the discharge standard required for leachate, and the treated water can be guaranteed to meet the primary discharge standard or water reuse standard of GB16889-1997. It is mainly used in projects such as landfill leachate, waste composting leachate and deep salt concentration with zero discharge.
The membrane used in DTNF-POS is also resistant to polar organic solvents and is encapsulated in a disc and tube without glue, so there is no risk of leaching in polar solvents during long-term operation.
Product Parameters
Disk Tube Reverse Osmosis (DTRO) Modules
Modules Model | Stabilized Salt Rejection (%) | Permeate Flow Rate (GPD) | Permeate Flow Rate (m³/d) | Active Area (ft²) | Active Area (m²) | Feed Concentration (mg/L) | Feed Pressure (psi) | Feed Pressure (MPa) |
DTRO-SW | 99.5 | 750 | 2.8 | 101 | 9.4 | 50000 | 1015 | 7.0 |
DTRO-BW | 98.5 | 1900 | 7.2 | 101 | 9.4 | 32000 | 800 | 5.5 |
Permeate flow and salt rejection based on the following standard conditions: NaCl solution, 25°C, pH 7.5-8 and 8% recovery. Flow performance variation: ±15%
Disk Tube Nanofiltration (DTNF) Module
Modules Model | Glucose Rejection (%) | Sucrose Rejection (%) | Permeate Flow Rate (m³/d) | Active Area (ft²) | Active Area (m²) | Stabilized Salt Rejection (mg/L) | Feed Pressure (psi) | Feed Pressure (MPa) |
DTNF–POS | ≥95 | ≥99.5 | 2600 | 9.8 | 101 | 2000 | 225 | 1.55 |
Permeate flow and salt rejection based on the following standard conditions: 25°C and 8% recovery. Flow performance variation: ±15%
Operating Instructions
Maximum Operating Pressure | 2320psi(16.0MPa) |
Maximum Pressure Drop Per Element | 130psi(0.90MPa) |
Short-Term Cleaning (30 min.) pH Range | 2-12 |
Continuous Operation pH Range | 6-9 |
Free Chlorine Tolerance | 0.1mg/L |